guest:Z23,1n
root:Vele4,8n phpbb3:oc74ITxx, sympa:oc74ITxx, mailman:Z23,1n dp_user:Z23,1n
postgres:oc74ITxx, skoumal:10.adar annis:Z23,1n
admin:Vele4,8n
skoumal:...
$ annis-admin.sh init -u annis -d annis -p Z23,1n -Poc74ITxx, INFO - Loaded JDBC driver: org.postgresql.Driver - 997 ms WARN - No corpus configuration loaded due to missing database connection. - 1491 ms INFO - initializing database - 1544 ms INFO - Creating Annis database and user. - 1544 ms INFO - creating user: annis - 1957 ms INFO - creating database: annis ENCODING = 'UTF8' TEMPLATE template0 - 1965 ms INFO - installing stored procedure language plpgsql - 2757 ms WARN - plpqsql was already installed: StatementCallback; bad SQL grammar [CREATE LANGUAGE plpgsql]; nested exception is org.postgresql.util.PSQLException: ERROR: language "plpgsql" already exists - 2844 ms INFO - creating trigger function: unique_toplevel_corpus_name - 2844 ms INFO - creating ANNIS database schema (annopool) - 2882 ms INFO - creating ANNIS database schema indexes (annopool) - 3868 ms INFO - populating the schemas with default values - 4018 ms INFO - creating immutable functions for getting annotations from the annotation pool - 4051 ms INFO - Wrote database configuration to /usr/local/annis-service-3.0.1/conf/database.properties - 4069 ms
admin:Z23,1n
finlib_2.11-1_amd64.deb
, manatee-open_2.33.2-1ubuntu1_amd64.deb
, manatee-open-python_2.33.2-1ubuntu1_amd64.deb
, bonito2-open_2.68-1_all.deb
a bonito2-open-www_2.68-1_all.deb
.libantlr3c
:# apt-get install libantlr3c-3.2-0
a udělat symlink pro libantlr3c.so
(vyzkoušet encodevert
).
# mkdir /var/lib/ske
# dpkg -i finlib_2.11-1_amd64.deb \ manatee-open_2.33.2-1ubuntu1_amd64.deb \ manatee-open-python_2.33.2-1ubuntu1_amd64.deb \ bonito2-open_2.68-1_all.deb \ bonito2-open-www_2.68-1_all.deb
# cd /usr/share/pyshared # mv /usr/lib/python2.6/dist-packages/manatee.py . # mv /usr/lib/python2.6/dist-packages/_manatee.so . # cd /usr/lib/python2.7/dist-packages/ # ln -s ../../../share/pyshared/manatee.py # ln -s ../../../share/pyshared/_manatee.so
# cd /var/lib/bonito2 # chown www-data cache # chown www-data subcorp
/var/lib/bonito2/htpasswd
./var/lib/manatee
a upravit skript /usr/share/bonito2/run.cgi
/var/www/bonito2/run.cgi
.$ sudo bash -l # export HOME=/root # cpan -e[f] MODULE
/etc/nsswitch.conf
je třeba přidat řádekautomount: files
idmapd
: do /etc/idmapd.conf
vyplnitDomain = ruk.cuni.cz
sympa
: /var/spool/sympa
a /var/lib/sympa
na sympa:sympa
<del>
* <del>opravit /etc/sympa/wwsympa.conf
: use_fast_cgi 1